All EMT Novel products are equipped with the innovative EMT multi-layer core transducer with titanium/sapphire cantilever. Incredible realistic performance is achieved, while at the same time the tried and trusted EMT typical specs are respected. The generator is integrated into a monobloc structure, milled from a solid block of magnesium. Thus both rigidity and resonance behaviour have been significantly improved.

Besides the standard EMT tonearm-connection, we offer the option INT (Ortofon A compatible) and option X (for SME standard). Furthermore, we manufacture 1/2 and 1/4 coil for lower impedance versions on request.

The TSD Novel features a Multi-Radius diamond shape. It is is fully compatible with the previous TSD 15.

Diamond: MR HP
Cantilever: Titanium / Sapphire
Transducer: EMT multi layer core technology
Connection: EMT
Vertical Tracking Angle: 23°
Weight: 17.5g
Tracking force: 2,2g
Output Transfer Level: 0,21mVs/cm
Compliance: 12µm/mN
Frequency response: 20 - 25‘000Hz
Impedance: 2x 18Ω
Recommended load: 200 - 300Ω